Product Introduction
UPS input/output cabinet is a device tailored to the characteristics of UPS uninterruptible power supply. It includes an input distribution cabinet, a UPS, and an output distribution cabinet. The output is input to the UPS through a cable, and the UPS stores it to become a stable three-phase power output. The output is supplied to external loads through the cable after passing through the output distribution cabinet. It has the characteristics of complete functionality, compact structure, stability and reliability, flexible deployment, and easy maintenance. Suitable for data centers in power, hospitals, government agencies, banks, communications, small and medium-sized enterprises, and large and medium-sized enterprises.
PRODUCT FUNCTION
Adopting a standard 19 inch cabinet body, the interior adopts a modular design, neat and beautiful. The shell adopts a glass door (mesh door) design, which is intuitive and reliable. The top and bottom of the cabinet are both equipped with cable holes, allowing cables to enter from the cable duct in the computer room or from the cable trench.
The molded case circuit breaker adopts fixed installation, while the miniature circuit breaker adopts rail card installation. Combined with highly modular design, it provides great convenience for fast and simple installation and troubleshooting maintenance.
Internal unified zero and ground bars can effectively ensure grounding.
Each branch is equipped with overload and short-circuit protection functions, and can also be equipped with fire linkage control, which has stable and reliable performance.
Product specifications and models
Name | Specification Model | Dimensions | Remarks |
---|---|---|---|
UPS Power Distribution Cabinet | IOC100A-CMH12/PT-D(S) | 600mm(W) * 600mm(D) * 2000mm(H) | IOC100A represents the current capacity of the main switch. 12, 24, 36, 48 represent the number of branch circuit breakers. PT represents a common column head cabinet, JM represents a precision column head cabinet. D represents a single - circuit, and S represents a double - circuit. |
UPS Power Distribution Cabinet | IOC100A-CMH12/JM-D(S) | 600mm(W) * 800mm(D) * 2000mm(H) | |
UPS Power Distribution Cabinet | IOC100A-CMH24/PT-D(S) | 800mm(W) * 800mm(D) * 2000mm(H) | |
UPS Power Distribution Cabinet | IOC100A-CMH24/JM-D(S) | 800mm(W) * 600mm(D) * 2000mm(H) | |
UPS Power Distribution Cabinet | IOC100A-CMH36/PT-D(S) | 600mm(W) * 800mm(D) * 2000mm(H) | |
UPS Power Distribution Cabinet | IOC100A-CMH36/JM-D(S) | 600mm(W) * 1000mm(D) * 2000mm(H) | |
UPS Power Distribution Cabinet | IOC100A-CMH48/PT-D(S) | 800mm(W) * 800mm(D) * 2000mm(H) | |
UPS Power Distribution Cabinet | IOC100A-CMH48/JM-D(S) | 800mm(W) * 1000mm(D) * 2000mm(H) |